OSHA emergency action plan requirements: 29 CFR 1910.38, line by line
OSHA's emergency action plan rule is 29 CFR 1910.38. When another OSHA standard calls for a plan, it must be written (or explained out loud with 10 or fewer employees), cover six minimum elements, use an alarm with a distinct signal for each purpose, have trained evacuation helpers, and be reviewed with each employee. The rule was last rewritten on November 7, 2002, and reads the same on eCFR on November 16, 2026.
What does 29 CFR 1910.38 require?
Six paragraphs, (a) to (f), and all six apply to every plan another Part 1910 standard calls for. The text below is OSHA's, shortened; it has read this way since the November 7, 2002 rewrite (67 FR 67961), checked on eCFR November 16, 2026.
| Paragraph | What it says | What it means for the plan |
|---|---|---|
| (a) Application | A plan is needed "whenever an OSHA standard in this part requires one" | The rule sets the contents; another standard sets who needs it |
| (b) Written or oral | In writing, kept at the workplace, open to employees; 10 or fewer employees may be told orally | Keep a copy where people work, not only at head office |
| (c) Minimum elements | Reporting; evacuation with type and route assignments; critical operations; head count; rescue and medical duties; contacts | The six sections every template must have |
| (d) Alarm | Have and maintain an alarm with a distinctive signal for each purpose, meeting 1910.165 | Say what each signal means, and test it |
| (e) Training | Designate and train employees to help others evacuate | Name the helpers in the plan |
| (f) Review | Review the plan with each employee at three moments | On hire, when duties change, when the plan changes |
Each of the six elements in (c) is a blank in the emergency action plan template, with an example line to replace.
Who must have an OSHA emergency action plan?
An employer covered by a standard that calls for one: 15 rules in Title 29 do, counted on eCFR on November 16, 2026. 1910.38 itself requires nothing until one of them applies. Six require a plan wherever they apply (powered platforms, process safety management in general industry and construction, grain handling, marine terminals and longshoring), four wherever an emergency with a listed chemical is possible, and five only in a set situation or as the condition of an exemption.
OSHA's own questionnaire checks for total flooding extinguishing systems, fire alarms delayed over 30 seconds, process safety management, grain handling, three listed chemicals, and evacuating everyone during a hazardous substance release. It also comes up through portable fire extinguishers: under 1910.157(a) and (b), having everyone leave instead of fighting a fire, or letting only designated employees use extinguishers, exempts you from some or all of that rule only with a plan.
Every rule, with the paragraph and the trigger, is in the 2026 rules and templates data, as a table and a CSV.
Does a small business need a written emergency action plan?
Not with 10 or fewer employees: 1910.38(b) lets that employer communicate the plan orally. The same cut-off appears in the fire prevention plan rule (1910.39(b)), the construction rule (1926.35(e)(3)) and the alarm rule, where 1910.165(b)(5) accepts a shouted warning in a workplace of 10 or fewer if everyone can hear it. The six elements still apply, so a small shop still decides how people report, where they meet and who counts them. Oregon OSHA's free sample for small businesses is two pages.
What alarm does an emergency action plan need?
One everyone can notice and tell apart. 29 CFR 1910.165, the alarm rule 1910.38(d) points to, asks for an alarm heard or seen above the workplace's noise and light, distinctive for each action the plan assigns, and allows tactile devices for anyone who couldn't otherwise notice it. Read on eCFR November 16, 2026, it also requires:
- Reporting explained. Tell each employee the preferred way to report (pull box, PA, radio or phone), and post emergency numbers near phones when phones are the way.
- Testing. A non-supervised system every two months, using a different pull station each time; a supervised system at least once a year.
- A back-up. Runners or phones while the system is out of service.
What training and review does OSHA require for an emergency action plan?
Two things, in 1910.38(e) and (f). The employer designates and trains employees to help others leave safely. Then the plan is reviewed with each employee when it is written or they start, when their duties under it change, and when it changes. 1910.38 sets no drill schedule. Some triggering rules add their own training: grain handling (1910.272(e)) requires safety training at least once a year. Texas's sample program, revised January 2023, asks for drills at least annually as its own policy.
When do you also need a fire prevention plan?
When a standard asks for one, usually beside an emergency action plan. Five of the 15 rules do, read November 16, 2026: the extinguisher exemptions in 1910.157 and the chemical rules for ethylene oxide (1910.1047), methylenedianiline (1910.1050 and 1926.60) and 1,3-butadiene (1910.1051). 29 CFR 1910.39 has the same written-or-oral rule and five elements:
- Major fire hazards, how the materials are handled and stored, ignition sources and their control, and the protection equipment for each hazard.
- How flammable and combustible waste is kept from building up.
- Upkeep of the safeguards on heat-producing equipment.
- Who maintains equipment that prevents or controls ignition sources.
- Who controls fuel source hazards.
Employees are told the fire hazards of their job on their first assignment, under 1910.39(d). ePlan, made by this site's publisher, drafts both plans together from the building's address: the opening of each draft free, $49 for the full draft and its Word file (November 16, 2026).
What changes on a construction site?
The rule number, the order and the alarm. Construction uses 29 CFR 1926.35, dated June 30, 1993 (58 FR 35083): the same six elements with escape procedures listed first, an alarm under 1926.159 with a distinctive signal for each purpose, a stated type of evacuation, the same three review moments, and the same oral option for 10 or fewer employees. Three construction rules call for a plan, read November 16, 2026: methylenedianiline (1926.60, with the 1910.38 and 1910.39 elements), process safety management (1926.64, which follows 1910.119) and hazardous waste operations (1926.65, under 1926.35).
What do OSHA State Plans add?
Their own wording, and sometimes a wider reach. 22 OSHA-approved State Plans cover private and public employers and 7 cover only public employees, each required to be at least as effective as federal OSHA (OSHA's State Plans page, read November 16, 2026). Three examples:
- California, 8 CCR 3220. The same elements and oral option, but the scope line reads "This section applies to all emergency action plans", without the federal limit to plans another OSHA standard requires.
- Oregon, OAR 437-002-0042. Oregon OSHA's own rule, with its free two-page sample.
- Washington, WAC 296-24-567. Emergency action plans and fire prevention plans in one section, from Labor and Industries.
What does a missing emergency action plan cost?
Up to $16,550 per serious or other-than-serious violation, and up to $165,514 per willful or repeated one (at least $11,823 when willful), under 29 CFR 1903.15(d) for penalties proposed after January 15, 2025, read on eCFR November 16, 2026; OSHA made no inflation increase for 2026 (OSHA memo, May 21, 2026). Failing to fix a cited problem costs up to $16,550 a day. These are maximums; this page has no figure for how often OSHA cites 1910.38.
How was this page checked?
Every quotation and figure was read on eCFR's current Title 29, and the State Plan counts on osha.gov, on November 16, 2026. The 15 rules come from searching Title 29 for "1910.38" and "emergency action plan" and reading each hit; a plan named only in a non-mandatory appendix was left out.
Questions
Is 29 CFR 1910.38 the same as an OSHA emergency action plan requirement for all businesses?
No. 29 CFR 1910.38 sets what an emergency action plan must contain, and it applies whenever another OSHA standard in Part 1910 requires a plan. It does not on its own require every employer to have one.
Does OSHA require fire drills in an emergency action plan?
No. 29 CFR 1910.38 requires trained evacuation helpers and a review of the plan with each employee, but it sets no drill schedule. Many state and local fire codes do, so check with your fire marshal.
Who enforces the emergency action plan rule in my state?
Federal OSHA, unless your state runs one of the 22 OSHA-approved State Plans that cover private employers, such as Cal/OSHA under 8 CCR 3220, Oregon OSHA under OAR 437-002-0042 or Washington L&I under WAC 296-24-567.
More on OSHA rules
- Emergency action plan rules and templates, 2026 data: the 15 rules and nine template sources, with CSVs.
- Emergency action plan template: the eight parts to fill in, and nine sources compared.
- Fire prevention plans, training and review, and construction sites are answered above on this page.
About this page
This guide is published by Winding AI, Inc., the company that makes ePlan, one of the nine template sources compared on the home page. We earn money when someone pays ePlan, and nothing from agencies or other products named here. It is a summary of the rule, not legal advice: OSHA's text and your State Plan's rules govern. Corrections: support@winding.ai.